Challenge
Hidden toilet leaks are one of the most common—and costly—sources of water waste in multifamily properties. Even relatively small leaks can waste hundreds of gallons of water each day, increasing both water and sewer costs while creating unnecessary maintenance activity and resident complaints.
A large mixed-use high-rise community in Bronx, New York sought a more proactive approach to identifying toilet leaks before they affected operations. Like many multifamily properties, maintenance personnel traditionally relied on resident reports or periodic inspections to identify plumbing problems. Unfortunately, these methods often allow hidden leaks to continue for days, weeks, or even months before corrective action is taken.
The property wanted a solution capable of continuously monitoring toilet performance, identifying abnormal operating conditions in real time, and providing maintenance personnel with actionable information before small plumbing issues became costly utility expenses.
The objectives included:
• Detect hidden toilet leaks before excessive water loss occurs
• Reduce unnecessary water and sewer expenses
• Improve maintenance response time
• Minimize manual inspections
• Increase operational visibility across the property
To provide additional operational visibility, WM1200 Hot and Cold Water Submeters
were installed to monitor apartment water consumption. The combination of fixture-level monitoring and apartment-level usage data enables maintenance personnel to identify unusual consumption patterns that may indicate hidden plumbing issues.
Solution
To address these challenges, the property implemented H2O Degree’s intelligent
wireless water management platform utilizing LoRaWAN® communications and cloud-based analytics.
The deployment combined fixture-level leak detection, apartment water submetering,
wireless communications, and centralized monitoring to provide continuous visibility into toilet operation and building water usage.
Optimizing the Metering Strategy
The project was originally designed with water meters installed on the building risers.
During the system evaluation, H2O Degree demonstrated that installing meters at
individual toilets would provide significantly greater operational value at a more
advantageous installed cost.
Riser-level metering would provide combined consumption data but would not identify which individual units or fixtures were responsible for excessive water use. By moving the meters to the toilet level, property management gained unit-level visibility needed to identify abnormal usage, locate leaks and target repairs.
L54120 wireless water meters were installed throughout the property to continuously
monitor fixture activity. By analyzing toilet operating behavior, the sensors identify
conditions that commonly indicate developing plumbing problems, including:
- Flapper failures
- Stuck fill valves
- Silent running toilets
- Continuous flow conditions
- Intermittent leak events
H2O Degree’s Smart Metering System can provide apartment- and fixture-level consumption data and leak reports, enabling maintenance personnel to identify unusual usage patterns, pinpoint potential plumbing issues, and respond more quickly.
All devices communicate through H2O Degree’s LoRaWAN® wireless network. Unlike traditional monitoring systems that require extensive wiring or dependence on resident Wi-Fi networks, the LoRaWAN architecture provides reliable long-range communication throughout the property while simplifying installation.
Data from each device is securely transmitted to the H2O Degree Cloud Server, where cloud analytics continuously evaluate fixture activity and water usage. When abnormal operating conditions are detected, automated alerts are immediately delivered to maintenance personnel by email or text message, allowing rapid investigation and corrective action before significant water loss occurs.
Operational Benefits
Real-Time Leak Detection – Continuous fixture monitoring allows maintenance personnel to identify abnormal toilet operation as it occurs rather than relying on resident complaints or reviewing monthly utility bills. Automated alerts help reduce response times and minimize unnecessary water loss.
Reduced Water and Sewer Costs – Early identification of developing toilet leaks allows maintenance personnel to resolve problems before excessive water consumption results in higher utility expenses. Even relatively small leaks that might otherwise remain unnoticed can be quickly identified and corrected.
Improved Maintenance Efficiency – Rather than spending valuable time conducting routine inspections or responding to resident complaints, maintenance teams receive actionable notifications identifying fixtures that require attention. This enables staff to prioritize maintenance activities and improve overall productivity.
Enhanced Operational Visibility – The combination of fixture-level leak detection and apartment water submetering provides property management with greater visibility into building water usage. Continuous monitoring helps identify abnormal
consumption patterns while supporting proactive maintenance strategies. Unit-level usage patterns may also help management identify potential unauthorized occupancy for further investigation.
Improved Resident Experience – Identifying plumbing issues earlier helps minimize resident inconvenience while reducing the likelihood of prolonged leaks that can negatively affect tenant satisfaction.
Scalable Smart Building Infrastructure – The deployment establishes a flexible wireless infrastructure capable of supporting additional H2O Degree monitoring solutions as operational requirements evolve.
Reliable Wireless Communication for High-Rise Buildings
Reliable wireless communication can be challenging in large multifamily buildings due to reinforced concrete construction, mechanical rooms, elevator shafts, and long communication distances.
H2O Degree’s LoRaWAN® platform is designed specifically for these environments, providing dependable long-range wireless communication with low-power battery operation and minimal IT infrastructure requirements. The architecture enables building-wide connectivity without relying on resident Wi-Fi networks or extensive wiring, making it well suited for both new construction and retrofit projects.
Supporting Operational Efficiency
Beyond identifying hidden toilet leaks, the deployment provides property management with valuable operational intelligence that supports more efficient building operations. Continuous monitoring helps maintenance personnel respond more quickly to plumbing issues, improves visibility into water consumption patterns, supports conservation initiatives, and reduces unnecessary utility expenses. By transforming hidden plumbing issues into actionable operational data, property teams can make more informed maintenance decisions while improving overall building performance.
Return On Investment
The operational value of intelligent leak detection extends far beyond water conservation. By providing continuous monitoring and automated alerts, H2O Degree helps multifamily operators:
- Reduce unnecessary water and sewer expenses
- Minimize labor associated with leak detection
- Improve maintenance productivity
- Resolve plumbing issues faster
- Increase operational visibility
- Support long-term asset performance
Every property is different, but the combination of reduced utility costs, improved maintenance efficiency, and proactive leak detection creates multiple opportunities to improve operational performance while protecting net operating income.
Conclusion
By implementing H2O Degree’s intelligent wireless toilet leak detection solution, this Bronx mixed-use high-rise transitioned from reactive plumbing maintenance to proactive water management. The decision to move from the originally specified riser-level metering approach to toilet-level monitoring transformed the project from simply measuring water consumption into a long-term water-management strategy designed to identify waste, support targeted repairs, and sustain water and sewer savings. The deployment demonstrates how intelligent fixture-level monitoring can help multifamily operators transition from reactive maintenance to data-driven water management while protecting both operating budgets and resident satisfaction.